| Sign In to gain access to subscriptions and/or personal tools. |
The Test-Retest Reliability of 2 Mobility Performance Tests in Patients With Chronic StrokeFaculty of Occupational Therapy, College of Health Science, Kaohsiung Medical University, Kaohsiung, Taiwan, Department of Rehabilitation, Kaohsiung Medical University Hospital, Taiwan
School of Occupational Therapy, College of Medicine, National Taiwan University, Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan
Department of Rehabilitation Medicine, Kaohsiung Municipal Hsiao-Kang Hospital, Kaohsiung, Taiwan, Faculty of Health, Medicine, Nursing and Behavioral Sciences, Deakin University, Melbourne, Australia
Department of Rehabilitation, Kaohsiung Medical University Hospital, Taiwan
Faculty of Physical Therapy, College of Health Science, Kaohsiung Medical University, Kaohsiung, Taiwan, jhlin{at}kmu.edu.tw Objective. This study examined test-retest agreement and measurement errors for the Rivermead Mobility Index (RMI) and the Mobility subscale of the Stroke Rehabilitation Assessment of Movement (M-STREAM) in patients with chronic stroke and mild to moderate disability. The authors aimed to determine the level of agreement between test and retest as well as the extent to which a mobility score varies on test-retest measurements. Methods. Both mobility measures were tested on 50 chronic stroke patients twice, 7 days apart. Intraclass correlation coefficient (ICC2,1), a relative reliability index, was used to examine the level of agreement between test and retest. Absolute reliability indices, including the standard error of measurement and the smallest real differences, were used to determine the extent to which the mobility scores varied due to chance variation in measurement. Results. Test-retest agreements were excellent for both mobility measures. The standard errors of measurement of the RMI and the M-STREAM, representing the smallest change threshold that indicates a real improvement (beyond measurement error) for a group of individuals, were 0.8 and 1.5, respectively. The smallest real differences of the RMI and the M-STREAM, exhibiting the smallest change threshold that indicates a real improvement for a single individual, were 2.2 and 4.2, respectively. Conclusion. The RMI and the M-STREAM have high agreement between the test-retest measurements with acceptable measurement errors due to variation in measurement. The 2 measures can be used by clinicians and researchers to assess the mobility performance and monitor changes over time in stroke patients.
Key Words: Mobility Walking Stroke Outcome measures Reliability.
This version was published on July
1, 2007 Neurorehabilitation and Neural Repair, Vol. 21, No. 4,
347-352 (2007) This article has been cited by other articles:
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
